Toyota Corolla + 1. Maintenance instruction + 2. Maintenance - 3. Engines + 3.1. Petrol engines + 3.2. Diesel engine - 3.3. Engine electric equipment 3.3.1. Specifications 3.3.2. Battery 3.3.3. Power cables 3.3.4. System of ignition 3.3.5. Ignition coil 3.3.6. Ignition distributor 3.3.7. Check and installation of the moment of ignition 3.3.8. Block of electronic ignition 3.3.9. Induction sensor 3.3.10. System of a charge of the battery 3.3.11. Generator 3.3.12. Generator details 3.3.13. System of launch of the engine 3.3.14. Starter electric motor + 4. Cooling systems, heating + 5. Fuel, exhaust systems + 6. System of decrease in toxicity + 7. Transmissions + 8. Coupling and half shafts + 9. Brake system + 10. Suspension bracket and steering + 11. Body + 12. Electric equipment
|
Generator details (standard option)
1. Back cover 2. Brush holder 3. Insulating plug 4. Rectifier assembled 5. Rubber buffer 6. Back flange of the case 7. Holder 8. Mud-reflector 9. Tension regulator 10. Brush holder cover 11. Contact plate of the rectifier
|
12. Rotor 13. Bearing cover 14. Back bearing 15. Forward bearing 16. Pulley 17. A forward cover (assembled with the stator) 18. Holder 19. Bearing cover 20. Persistent washer |
Details of installation and drive of the generator
1. Drive belt 2. Coupling bolt 3. Lock bolt |
4. Main wire of the generator 5. Adjusting bolt 6. Generator 7. Socket |
Removal
PERFORMANCE ORDER |
1. Disconnect the battery from weight. |
|
2. Disconnect sockets from the generator. |
3. Weaken adjusting, coupling and lock bolts of the generator (see rice. Detail of installation and drive of the generator). |
4. Turn off and get adjusting and coupling bolts from an adjusting arm of the generator. |
5. Remove the generator and an arm from the engine. |
6. If you decided to replace the generator, then at acquisition of the new unit capture with yourself the old generator. Make sure that new (or repaired) the generator in accuracy corresponds to replaced. Pay attention to conclusions – their number, the sizes and a relative positioning has to be same, as on the replaced unit. At last, check marking. Marking has to be or is stamped on the case, or printed on a label and pasted on the case. Make sure that numbers on the new and replaced units coincide.
|
7. On many new (or repaired) generators there are no pulleys therefore it is necessary to rearrange a pulley from the replaced unit. At acquisition of the new generator consult concerning installation of a pulley, in some workshops and points of sale consultation is given free of charge.
|
|
|
|