Toyota Corolla

1992-1998 of release

Repair and operation of the car



Toyota Corolla
+ 1. Maintenance instruction
+ 2. Maintenance
+ 3. Engines
+ 4. Cooling systems, heating
+ 5. Fuel, exhaust systems
- 6. System of decrease in toxicity
   6.1. Specifications
   6.2. Electronic control system
   6.3. Electronic control unit
   + 6.4. System of onboard diagnostics
   - 6.5. Sensors of system of automatic control of the engine
      6.5.1. Sensor of temperature of cooling liquid
      6.5.2. Sensor of concentration of oxygen
      6.5.3. Sensor of an angle of rotation of a butterfly valve (TPS sensor)
      6.5.4. The sensor of absolute pressure on the soaking-up collector (MAR-sensor)
      6.5.5. The air temperature sensor on the soaking-up collector (IAT sensor)
      6.5.6. Temperature sensor of system of recirculation (EGR sensor)
      6.5.7. Car speed sensor (VSS sensor)
      6.5.8. Detonation sensor
      6.5.9. Sensor of an angle of rotation of the crankshaft
   6.6. System of catching of vapors of gasoline
   6.7. System of recirculation (EGR system)
   6.8. System of compulsory ventilation of a case (PCV system)
   6.9. Catalytic converter
+ 7. Transmissions
+ 8. Coupling and half shafts
+ 9. Brake system
+ 10. Suspension bracket and steering
+ 11. Body
+ 12. Electric equipment



bbeb4949

6.5.9. Sensor of an angle of rotation of the crankshaft

GENERAL INFORMATION

Installation site of the sensor of an angle of rotation of the crankshaft

On some cars of the last years of release the sensor of an angle of rotation of the crankshaft (it is specified by an arrow) is about a cover of a gear belt, near a pulley. The sensor gives a signal in the control unit on the basis of which the crankshaft angle of rotation precisely is defined.

Check

PERFORMANCE ORDER
1. Measure crankshaft sensor resistance. It has to be within 1,630–3,225 Ohms depending on temperature: at temperature increase resistance of the sensor increases. If the measured values of resistance do not correspond to this range, then replace the sensor.
2. For replacement of the sensor remove a pulley (see subsection 3.1.1.6), disconnect the socket and turn out screws of fastening of the sensor.